Agrawal, Ankur (2012) Seismic Evaluation of Institute Building,NIT Rourkela. BTech thesis.
Abstract
There
are many buildings which do not meet the current seismic requirement
and suffer extensive damage during the earthquake. In 1960 when the
institute building of NIT Rourkela was constructed, the seismic loading
was not considered. The building is only deigned to take the dead and
live loads. Evaluating the building for seismic conditions gives an idea
whether the building is able to resist the earthquake load or not. The
objective is to evaluate an existing building for earthquake
performance. Firstly preliminary evaluation is done and then detailed
evaluation is carried out. For applying earthquake loads, equivalent
static lateral force method is used according to IS 1893(Part 1):2002.
The Demand Capacity Ratio (DCR) is carried out for beams and columns in
order to evaluate the member for seismic loads. Since the reinforcement
details of the building were not available as it is more than 50 years
old, Design-1 is prepared applying only DEAD and LIVE loads according to
IS 456:2000. This helps in estimating the reinforcement present in the
building and in assuming that this much reinforcement is present. In
Design-2 seismic loads are applied and from this demand obtained from
design-2 and capacity from design -1, the DCR is calculated. If demand
is more than capacity, the member fails and vice versa. STAAD-Pro V8i is
used for loading and designing the building.